Bulk Portable
Electric Cable |
| |
| "Neoprene Jacket" |
SO- |
Hard service cord, oil resistant neoprene
jacket, 600volt 60 °C to 90° C |
| SJO- |
Junior, 300volt neoprene jacket. Same construction
|
TYPE SJO |
| Cat
NO. |
Conductors |
NOM
O D
Inches |
STD
PUT
UP |
Weight
M FT
Pounds |
| NO |
AWG Size |
| 12301
12303
12305
12307
12309
12311
12313
12315
12317
12319 |
2
3
2
3
2
3
4
2
3
4 |
18
18
16
16
14
14
14
12
12
12 |
.280
.300
.305
.325
.334
.360
.390
.405
.425
.465 |
250ft
250ft
250ft
250ft
250ft
250ft
250ft
250ft
250ft
250ft |
46
58
56
78
76
99
121
113
142
179 |
|
TYPE SO |
|
Cat NO. |
Conductors
|
NOM
O D Inches |
STD
PUT UP |
Weight
M FT
Pounds |
| NO |
AWGSize |
| 12402
12404
12406
12408
12410
12412
12414
12416
12418
12420
12422
12424
12425
12426
12428
12429
12430
12431 |
2
3
2
3
2
3
4
2
3
4
3
4
5
3
4
5
3
4 |
18
18
16
16
14
14
14
12
12
12
10
10
10
8
8
8
6
6 |
.340
.360
.365
.385
.495
.520
.560
.565
.590
.640
.650
.700
.760
.655
.715
.785
.730
.845 |
250ft
250ft
250ft
250ft
250ft
250ft
250ft
250ft
250ft
250ft
250ft
250ft
250ft
250ft
250ft
250ft
250ft
250ft |
71
84
83
101
142
171
212
189
230
281
293
357
461
354
450
560
530
661 |
|
| |
| "Plastic Jacket" |
| |
|
| ST- |
Hard service cord, all plastic construction 600 bolt
jacket, 60 C |
| SJT- |
Junior, 300volt plastic jacket. Same construction
as ST but thinner, lighter jacket. |
| STO- |
Same construction as ST but with oil resistant thermoplastic
outer jacket 600 volt 60 C |
| SJTO- |
Same construction as SJT but with oil resistant Thermoplastic
outer jacket. |
As can be seen, the plastic jacke identification
system is essentially the same as the neoprene group with the addition
of "T" which indicates thermo-setting plastic. |
| |
"Primary Wire"
This wire is usually single conductor and has the same circular
mill rating as portable cord, but has fewer strands and the strands
are thicker. This cord is therefore less flexible, but is also less
expensive. It is sometimes called booster cable in the 18 gauge
through #8 gauge and it is called starter cable in the 6 gauge through
2/0 gauge. |
| |
"Trailer Wire"
Bonded Primary Each conductor is individually insulated and colored.
The conductors are then bonded together in parallel construction
and do not have a jacket cover. They are in 3 conductors or 4 conductors
sizes. Colors are: for 3 conductor, yellow, brown, green: and for
4 conductor, yellow, brown, green, white. |
| |
PRICE IN EFFECT AT TIME OF DELIVERY.
We reluctantly have had to adapt the pricing policies of our suppliers,
i.e. Prices in Effect at Time of Delivery.
Plese phone for our Current quotation. |